Swinburne
Browse

A new two-tier strength assessment approach to the diagnosis of weakness in intensive care: An observational study

Download (507.43 kB)
journal contribution
posted on 2024-07-26, 14:31 authored by Selina M. Parry, Sue Berney, Catherine L. Granger, Danielle L. Dunlop, Laura Murphy, Doa El-AnsaryDoa El-Ansary, René Koopman, Linda Denehy
Introduction: Intensive care unit-acquired weakness (ICU-AW) is a significant problem. There is currently widespread variability in the methods used for manual muscle testing and handgrip dynamometry (HGD) to diagnose ICU-AW. This study was conducted in two parts. The aims of this study were: to determine the inter-rater reliability and agreement of manual muscle strength testing using both isometric and through-range techniques using the Medical Research Council sum score and a new four-point scale, and to examine the validity of HGD and determine a cutoff score for the diagnosis of ICU-AW for the new four-point scale. Methods: Part one involved evaluation of muscle strength by two physical therapists in 29 patients ventilated >48 hours. Manual strength testing was performed by both physical therapists using two techniques: isometric and through range; and two scoring systems: traditional six-point Medical Research Council scale and a new collapsed four-point scale. Part two involved assessment of handgrip strength conducted on 60 patients. A cutoff score for ICU-AW was identified for the new four-point scoring system. Results: The incidence of ICU-AW was 42% (n = 25/60) in this study (based on HGD). In part one the highest reliability and agreement was observed for the isometric technique using the four-point scale (intraclass correlation coefficient = 0.90: kappa = 0.72 respectively). Differences existed between isometric and through-range scores (mean difference = 1.76 points, P = 0.005). In part two, HGD had a sensitivity of 0.88 and specificity of 0.80 for diagnosing ICU-AW. A cutoff score of 24 out of 36 points was identified for the four-point scale. Conclusions: The isometric technique is recommended with reporting on a collapsed four-point scale. Because HGD is easy to perform and sensitive, we recommend a new two-tier approach to diagnosing ICU-AW that first tests handgrip strength with follow-up strength assessment using the isometric technique for muscle strength testing if handgrip strength falls below cutoff scores. Whilst our results for the four-point scale are encouraging, further research is required to confirm the findings of this study and determine the validity of the four-point scoring system and cutoff score developed of less than 24 out of 36 before recommending adoption into clinical practice.

Funding

National Health and Medical Research Council

History

Available versions

PDF (Published version)

ISSN

1466-609X

Journal title

Critical Care

Volume

19

Issue

1

Pagination

52-

Publisher

BioMed Central Ltd.

Copyright statement

Copyright © 2015 Parry et al.; licensee BioMed Central. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Language

eng

Usage metrics

    Publications

    Categories

    No categories selected

    Keywords

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC