posted on 2024-07-13, 09:41authored byFariborz Moeinaddini
A mechanical explanation for the punching shear phenomenon at column-slab connection is developed on the basis of experimental observations and nonlinear Finite Element analysis. The load transfer mechanism from slab to column is used to formulate a punching shear failure criterion for reinforced concrete flat plates and post-tensioned floors under concentric loading.
History
Thesis type
Thesis (PhD)
Thesis note
Submitted in total fulfilment of the requirements for the degree of Doctor of Philosophy, Swinburne University of Technology, 2019.